Smashing Scatter Rare Microson Ultrasonic Cell Disruptor With CE Confirmed
Major Purposes
The ultrasonic cell disruptor can be used to smash animal or plant cells, bacteria, gemma
or tissue or scatter rare earth and various kinds of inorganic mineral powder.
It is an ideal device to speedup chemical, biological or physical reactions, and degass liquid.
The ultrasonic cell disruptor can prepare emulsoid of 1/100 micron,
homogenize mixture hard to be mixed polymerize some matters and separate out some other.
Generally speaking, it can process various functions such as distillation, smash, emulsification,
homogenization, soliquoid, aberrance, aerosol,quicken up exsolution and crystallization
and preparing different kinds of biological samples under an electron microscope.
Disposing of organic and inorgani compound safely and efficiently.
Mainly used for crush of virus and bacterium of the cell and tissue of the various of animal or plant,
crush and combination again of the various of inorganic compound.
Used in emulsification,separation, even,recovering and chemical reaction acceleration etc.
Widely used in the field of biochemistry,microbiology, pharmacology,medicine and etc.
Specification:
Type |
Full-length (mm) |
Frequency (KHz) |
Resonnce impedance () |
Capacity (pF)±10% |
Power (W) |
---|---|---|---|---|---|
CCH-3538L-20 |
310 |
20 |
15-30 |
10000 |
750 |
CCH-1624F-20 |
310 |
20 |
15-30 |
4000 |
100 |
Type Power(w ) Optional luffing rod Handle Sample Weight Plus duty cycle work
UH-100A 100 1/8″3/16″1/4″ 100ul~ 80ml 1%~99%
UH-250A 250 1/8″3/16″1/4″ 100ul~ 200ml 1%~99%
UH-500A 500 1/8″3/16″1/4″1/2″ 250ul~ 500ml 1%~99%
UH-800A 800 3/16″1/4″1/2″3/4″ 250ul~ 800ml 1%~99%
UH-950A 950 3/16″1/4″1/2″3/4″ 250ul~ 1000ml 1%~99%
UH-1200A 1200 3/16″1/4″1/2″3/4″ 50ml~ 1200ml 1%~99%
Matters Need Attention
1. The power supply parts for connection to the converter may not be connected to the power switch.
2. Shaped entered the "tip" head to ensure normal crushing effect is very important.
Lasting cavitation causes erosion stator end, lower output power.
The smoother the "tip" head light, sent to the power will be high in the samples.
"Tip" head of corrosion can speed up the further erosion, when the "tip" oscillator end face is not smooth,
please timely use polishing cloth or grinding wheel polishing.
3.Shall not touch the vibration of the probe
4. Power supply part of the converter when not connected, shall not be connected to the power switch.
5. 5. In order to ensure safety, please do not open the cabinet.